Here's the wiring:-
WB 2
violet K3 analogue-in e.g. AuxIn35
white / violet K3 pin 30, signal groundred 3 amp ignition switched live
black chassis ground
black / white chassis ground
Make sure that the pull-up resistor is not enabled for your selected analogue-in. This is done on the Input Channel Configuration screen. The 100 ohm buffer resistor, required for the Innovate LC1, is not required for the DynoJet Wide Band 2.
No configuration or calibration is required, the output is pre calibrated to (volts * 1.6) + 10 = AFR.
In the K3's AFR/Lambda Input Calibration screen set the input source to the analogue-in as used above and enter :-
Input Voltage AFR
0 10
1 11.6
2 13.2
3 14.8
4 16.4
5 18After the ECU has been updated with these settings, it will be possible to read the current AFR from the live adjustments screen. It will also be possible to use the K3's adaptive mapping and closed-loop fueling capabilities.